Interior Dimensions
|
Specifications
| See Notes |
- Working Width
- Working Depth (front of floor to rear)
- Working Height Floor to Ceiling
|
- 72" (1,828mm)
- 72" (1,828mm)
- 72" (1,828mm)
|
|
Exterior Dimensions
| | |
- Overall width with the door closed
- Overall width with the door open
- Overall length with the door closed
- Overall length with the door open
- Overall height
|
- 96” (2,438mm)
- 96” (2,438mm)
- 84” (2,133mm)
- 120” (3,048mm)
- 120” (3,048mm)
|
- Note 1,2,3
- Note 1,2,3
- Note 1,3
- Note 1,3
- Note 1
|
Temperature Capability
| | |
- Maximum interior working temperature
- Maximum heating rate (average air)
- Maximum cooling rate (average air)
- Thermal load during the test
- Temperature uniformity at steady state
|
- 550°F
- 3.1°F/min
- 5°F/min
- 1,000 lbs steel
- +/- 5 °F
|
|
Interior fabrication
| |
- Internal insulation
- Sheet metal
|
- 4” ceramic fiber (101.6mm)
- 18 GA Aluminized steel
|
Heating System
| |
|
- Electric, 51KW, 1 bank, Inconel sheathed
- Proportional SSR with backup contactor
|
Vacuum
| | |
- Vacuum Source Line Quantity
- Vacuum Source Line Size
- Computer-controlled valves on each line
- Resin filter trap
- Vacuum Probe Line Quantity
- Vacuum Probe Line Size
|
- 3
- ½” npt.
- VAC
- Yes
- 3
- 1/4" npt.
|
|
Thermocouples
| | |
- Thermocouple type
- Air temperature thermocouples
- Part temperature thermocouples
- Hi-Limit safety thermocouple
|
|
- Note 15
- Note 15,16
- Note 15
|
Control System
| |
- Primary Controller
- Control Software
- PLC and control hardware
- Report Printer
- Electrical enclosures
- PC enclosure
|
- Computer, Dell Optiplex
- CPC - Composite Processing Control
- Allen Bradley CompactLogix
- HP Color Deskjet 6940 (or Equiv)
- One, Nema-12, housing control and power
- None. PC to be placed on the integrated shelf.
|
Power System
| |
- Primary power
- Control power
- Full load amps
|
- 480V / 3PH / 60Hz
- 120V / 1PH / 60Hz
- 150FLA
|
|
Weight
| |
- Approximate shipping weight
|
|