Webinar recordings are part of the ASC support portal.
Sign in to watchNo account yet? Contact ASC support.Temperature and Pressure Float in CPC
About this webinar
CPC software includes temperature float and pressure float settings that help lower nitrogen, electricity, or fuel consumption during composite processing. In closed autoclave systems, pressure and temperature are physically linked. By allowing one parameter to rise or fall naturally alongside changes in the other, operators can reduce unnecessary heating, cooling, or pressurization.
The video demonstrates how to locate float configuration documentation on the ASC website, set float limits within CPC recipe segments, and inspect the underlying script logic. It also illustrates real-time behavior in a simulated run, showing how float status transitions and how PID outputs react when float limits are met.