Webinar recordings are part of the ASC support portal.
Sign in to watchNo account yet? Contact ASC support.Run Operations, Part 2: Mid-Run Changes and Data Analysis
Part 2 of 2 in the Run Operations series
About this webinar
This training session demonstrates complete end-to-end management of an autoclave cure cycle using CPC software. It covers selecting and transferring recipes, configuring batch items with specific thermocouple and vacuum probe attachments, executing pre-run integrity checks, and resolving run-start interlocks before initiating a run.
The demonstration highlights mid-run controls, including monitoring rate changes on the trend screen using trace lines, adjusting vacuum modes manually during execution, creating custom sensor display groups, and pausing or skipping recipe segments. It concludes with post-run operations, showing how to inspect numeric data logs, review override messages, and generate trend reports and quality cards.
This material serves autoclave operators, process technicians, and quality assurance personnel responsible for executing composite cure recipes and reviewing run data in CPC.