Sign in to watchNo account yet? Contact ASC support.CPC Trend Screen Troubleshooting
About this webinar
This session shows how to use the CPC trend screen, numeric reporting, and message logs to troubleshoot autoclave operational issues. It explains how to add and interpret system inputs and outputs—including system vacuum, vessel pressure, air and part thermocouples, fan VFD speeds, safety interlocks, and PID control outputs.
The presentation also covers secondary diagnostic tools in CPC, such as using trace lines on graph trends, setting up continuous text file input backups when no run is active, analyzing numerical save intervals to identify communication lag, and inspecting object and screen audit logs to track configuration changes.